Home
Over ons
Produkten
Downloaden
Technische Lib
Contact
Navraag
Sitemap
Links
 

Alarm & Audio & Elektronische Kabel

Belden gelijkwaardige kabels

Coax Kabels

Control Kabels

Fiber Optic Kabels

Flexibele Kabels

Instrumentatie Kabel

Lan kabels
Energie Kabel
Spoorweg Kabel

Robotica

Rollend materieel kabels
Rubber & Crane kabels
Beveiliging kabels

Telefoonkabels

Luchthaven Kabels

Bus kabels

Kabel Klieren

Data Kabels

Hitte detectie kabels
Hoge temperatuur kabels
Kabels snelweg
Marine, olie-, gas-en petrochemische Kabels
Speciaal Kabels
Spiraal Kabels
Thermokoppel Kabels
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
 

Telefoonkabels

 PVC Insulated Jumper Wires to CW 1109, CW 1257 & CW 1423

Aanvraag

The jumper wires are used for interconnection between terminal blocks at main distribution frames (MDF), cross connection cabinets (CCP) and distribution frames or boxes.

Normen

• CW 1109 (PVC T2)

• CW 1257 (Cross linked PVC)

• CW 1423 (PVC BT M154)

Bouw

Dirigenten
Solid annealed tinned copper 0.32/0.4/0.5/0.6/0.8/1.0mm as per class 1 of BS 6360/IEC 60228

Isolatie
PVC Type 2 to BS 6746 (CW 1109); Cross-linked PVC (CW 1257) & PVC (CW 1423)

Twisted Pairs
For CW 1109 & CW 1257, two insulated conductors are twisted into pairs with varying lays to minimize crosstalk. For CW 1423, one, two, three, four or five insulated conductors are twisted together with a right hand lay

Elektrische eigenschappen

CW 1109

Nominal Conductor Diameter

mm

0.32

0.4

0.5

0.6

0.8

1.0

7/0.2

Conductor Size

mm2

0.08

0.126

0.196

0.283

0.5

0.785

0.22

Maximum Conductor Resistance @20°C

Ω/km

234

148

95

65.9

36.7

23.3

89.9

Minimum Insulation Resistance @500V DC

MΩ.km

50

50

50

50

50

50

50

Minimum Insulation Thickness

mm

0.12

0.15

0.15

0.15

0.25

0.25

0.15

Maximum Insulated Conductor Diameter

mm

0.7

0.85

0.95

1.05

1.5

1.7

1.05

CW 1257

Nominal Conductor Diameter

mm

0.4

0.5

0.6

Conductor Size

mm2

0.126

0.196

0.283

Maximum Conductor Resistance @20°C

Ω/km

153

98

68.9

Minimum Insulation Resistance @500V DC

MΩ.km

50

50

50

Minimum Insulation Thickness

mm

0.25

0.25

0.25

Maximum Insulated Conductor Diameter

mm

1.0

1.10

1.20

CW 1423

Nominal Conductor Diameter

mm

0.5

Conductor Size

mm2

0.196

Maximum Conductor Resistance @20°C

Ω/km

98

Minimum Insulation Resistance @500V DC

MΩ.km

50

Minimum Insulation Thickness

mm

0.25

Maximum Insulated Conductor Diameter

mm

1.10

Mechanical and Thermal Properties

Temperature range during operation (fixed state): -30°C – +70°C
Temperature range during installation (mobile state): -20°C – +50°C
Minimum bending radius: 7.5 x Overall Diameter

Color Code

CW 1109 - as per IEC 60189-3
CW 1257 & CW 1423:

BLUE

ORANGE

GREEN

BROWN

GREY

WHITE

RED

BLACK

PINK

VIOLET

YELLOW

TURQUOISE

 

 

 

Afmetingen en het gewicht

CW 1109

Kabel-code

Aantal draden

Minimale isolatiedikte mm

Maximum Overall
Diameter
mm

Nominale Gewicht kg/km

0.32mm Conductor, 0.7mm Insulated Wire

TP1109-Y-1W032

1

0.12

0.7

1.5

TP1109-Y-2W032

2

0.12

1.3

3.0

0.4mm Conductor, 0.85mm Insulated Wire

TP1109-Y-1W04

1

0.15

0.85

1.8

TP1109-Y-2W04

2

0.15

1.45

3.6

0.5mm Conductor, 0.95mm Insulated Wire

TP1109-Y-1W05

1

0.15

0.95

2.2

TP1109-Y-2W05

2

0.15

1.65

4.8

TP1109-Y-3W05

3

0.15

2.35

6.6

0.6mm Conductor, 1.05mm Insulated Wire

TP1109-Y-1W06

1

0.15

1.05

2.8

TP1109-Y-2W06

2

0.15

1.75

5.6

0.8mm Conductor, 1.5mm Insulated Wire

TP1109-Y-1W08

1

0.25

1.50

5.5

TP1109-Y-2W08

2

0.25

2.50

11.0

1.0mm Conductor, 1.7mm Insulated Wire

TP1109-Y-1W10

1

0.25

1.70

6.5

TP1109-Y-2W10 2 0.25 2.60 13.0
7/0.2mm Conductor, 1.05mm Insulated Wire
TP1109-Y-1W7/02 1 0.15 1.05

2.5

TP1109-Y-2W7/02 2 0.15 2.35

5.0

CW 1257

Kabel-code

Aantal draden

Minimale isolatiedikte mm

Maximum Overall
Diameter
mm

Nominale Gewicht kg/km

0.4mm Conductor, 1.0mm Insulated Wire
TP1257-Y-1W04 1 0.25 1.0 2.0
TP1257-Y-2W04 2 0.25 1.8 4.0
0.5mm Conductor, 1.1mm Insulated Wire
TP1257-Y-1W05 1 0.25 1.1 2.5
TP1257-Y-2W05 2 0.25 2.0 5.0
0.6mm Conductor, 1.2mm Insulated Wire
TP1257-Y-1W06 1 0.25 1.2 2.9
TP1257-Y-2W06 2 0.25 2.2 5.8

CW 1423

Kabel-code

Aantal draden

Minimale isolatiedikte mm

Maximum Overall
Diameter
mm

Nominale Gewicht kg/km

0.5mm Conductor, 1.1mm Insulated Wire
TP1423-Y-1W05 1 0.25 1.98

2.5

TP1423-Y-2W05 2 0.25 2.5

5.0

TP1423-Y-3W05 3 0.25 3.0

7.5

TP1423-Y-4W05 4 0.25 3.8

10.0

TP1423-Y-5W05 5 0.25 4.6

12.5